Why Choose ZIQI Diesel Generators?
ZIQI offers premium industrial power solutions ranging from 10
kVA to 3000 kVA. Powered by world-class engines —
Cummins, Perkins, Yuchai, and Weichai — paired with
Stamford / Leroy Somer 100% copper-wound alternators
and DeepSea / SmartGen digital controllers. Available
in Open Type (for engine rooms with maximum ventilation) and Silent Type
(for noise-sensitive areas down to 65 dB). Every unit is factory-tested
at full load, rated for 50°C tropical ambient, and
shipped ready to connect. From hospital backup to mining camp prime
power — ZIQI generators keep your operations running.
Where Are Diesel Generators Used?
From emergency backup to continuous prime power — ZIQI
generators cover every scenario.
Essential for hospitals, data centers, telecom base stations, and
financial institutions. When mains power fails, the generator starts
instantly via ATS (Automatic Transfer Switch) to
support critical loads — typically within 10-15 seconds.
🏗️
Construction & Work Sites
Provides flexible power for cranes, welders, mixers, and lighting
towers where grid access is unstable or unavailable. Rugged design
with reinforced base frame ensures durability in dusty and harsh
environments.
⚡
Remote Area Prime Power
Serves as the primary power source for islands, mines, mountain
villages, and oil fields. Capable of Continuous Power
(COP) operation for 24/7 daily living and industrial
production with unlimited running hours.
🎤
Events & Temporary Venues
Perfect for outdoor concerts, exhibitions, sports events, and wedding
venues. Our Silent Type generators ensure low noise
operation (≤65-75 dB at 7m) so they don't disturb the event or
surrounding areas.
Core Components
Every ZIQI generator is built from internationally proven
subsystems.
System Breakdown
-
Diesel Engine: Cummins / Perkins / Yuchai /
Weichai — water-cooled, turbocharged.
-
Alternator: Stamford / Leroy Somer — 100%
copper winding, brushless, self-exciting.
-
Controller: DeepSea DSE6120 / SmartGen —
digital display, remote monitoring capable.
-
Cooling System: 50°C rated radiator with
tropical-grade coolant for harsh climates.
-
Base Frame: Heavy-duty steel with
anti-vibration dampers & integrated fuel tank.
-
Circuit Breaker: ABB / Delixi — rated for
generator output with short-circuit protection.
Power Rating Definitions
Understanding ESP, PRP, and COP helps you select the right
generator for your application.
Emergency Standby (ESP)
Maximum power for utility failure
backup. Limited to 500 hours/year with variable
load. No overload permitted. Typical use: hospitals, data
centers, office buildings.
Prime Rated (PRP)
Maximum power for unlimited
hours at variable load. Allows 10% overload for 1
hour every 12 hours. Typical use: construction sites, remote
operations.
Continuous Power (COP)
Maximum power for constant load,
unlimited hours. Used as the sole power source. No
overload. Typical use: island power, mining camps, off-grid
facilities.
Range of Premium Products
Available in Open Type and Silent Type configurations to
match your installation requirements.
Open Type

Silent Type

Silent Type —
Large Power

Open Type vs Silent Type — Which Do You Need?
Both types use the same engine and alternator. The
difference is the enclosure.
| Feature |
Open Type |
Silent Type |
| Noise Level (at 7m) |
85 – 100 dB(A) |
65 – 75 dB(A) |
| Best For |
Dedicated engine rooms, industrial plants |
Residential, hospitals, offices, events |
| Weather Protection |
Requires building or shelter |
Fully weatherproof canopy — outdoor OK |
| Maintenance Access |
Fully exposed — easy 360° access |
Side doors — slightly more effort |
| Footprint |
Smaller (no canopy) |
10-15% larger due to enclosure |
| Cost |
Lower — no canopy cost |
10-20% premium for soundproof housing |
| Transport |
Lighter, easier to move |
Heavier but includes lifting points |
Engine Brand Comparison
ZIQI offers multiple engine brands to match your budget
and project requirements.
| Criteria |
Cummins (USA) |
Perkins (UK) |
Yuchai (China) |
Weichai (China) |
| Power Range |
20 – 3000 kVA |
10 – 2500 kVA |
20 – 2000 kVA |
20 – 1500 kVA |
| Global Parts Network |
190+ countries |
170+ countries |
Asia / Africa / S. America |
Asia / Africa |
| Fuel Efficiency |
★★★★★ |
★★★★★ |
★★★★ |
★★★★ |
| Durability / Overhaul Interval |
20,000 – 30,000 hrs |
15,000 – 25,000 hrs |
12,000 – 20,000 hrs |
10,000 – 18,000 hrs |
| Price Level |
$$$$ |
$$$$ |
$$ |
$$ |
| Best For |
Critical facilities, export |
Telecom, commercial |
Cost-effective projects |
Budget-friendly, domestic |
Need a Diesel Generator Quote?
Tell us your required kVA, voltage, frequency, and whether you need Open
or Silent Type. We'll respond with a full technical proposal within 24
hours.
Frequently Asked Questions
What is the difference between Prime (PRP) and
Standby (ESP) power?
Prime Power (PRP) is for unlimited running hours
at variable load, with 10% overload allowed for 1 hour every 12
hours. Standby Power (ESP) is the maximum output during a utility
failure — limited to 500 hours per year, no overload. Choose ESP for
backup; choose PRP for continuous or semi-continuous use like
construction or remote areas.
What is the difference between Open Type and
Silent Type generators?
Both use the same engine and alternator. Open Type
has no enclosure — ideal for dedicated engine rooms with existing
ventilation. Silent Type adds a soundproof canopy that reduces noise
from 85-100 dB to 65-75 dB(A) at 7 meters, making it suitable for
residential areas, hospitals, offices, and outdoor events. The
Silent Type costs about 10-20% more.
What is the difference between Cummins and Yuchai
engines?
Cummins (USA) offers top-tier durability,
worldwide parts availability in 190+ countries, and overhaul
intervals of 20,000-30,000 hours — ideal for critical facilities and
export projects. Yuchai (China) delivers excellent heavy-duty
performance with overhaul intervals of 12,000-20,000 hours at a
significantly lower price point — ideal for cost-sensitive domestic
and regional projects. Both are proven in generator applications.
How do I calculate what size generator I need?
Add up the wattage (kW) of all equipment running
simultaneously. For motor loads, account for starting current which
can be 3-6× the running current — this is the most common sizing
mistake. Multiply your total by 1.25 for a safety margin. Example:
200 kW total load → select at least 250 kVA rated generator. Not
sure?
Send us your
equipment list and we'll calculate the optimal model for
free.
Does the generator come with a fuel tank?
Yes. Generators under 1000 kVA typically include a
base-mounted fuel tank capable of running 8 hours at full load.
Larger units above 1000 kVA may require an external bulk fuel tank,
which ZIQI can supply as an option. Daily fuel tank capacity can
also be customized at order time.
Can ZIQI generators run on both 50 Hz and 60 Hz?
Each generator is factory-configured for either 50
Hz (1500 RPM) or 60 Hz (1800 RPM). Specify your required frequency
when ordering. ZIQI supports both standards and can customize
voltage output — 230V, 400V, 480V, or other configurations — to
match your local grid requirements.
What is an ATS (Automatic Transfer Switch)?
An ATS monitors the mains power supply. When it
detects a failure, it automatically signals the generator to start
and transfers the load from mains to generator — typically within
10-15 seconds. When mains power returns, the ATS transfers back and
shuts down the generator. ZIQI supplies ATS panels as a standard
option for all standby installations.
What maintenance does a diesel generator require?
Routine maintenance includes: oil and filter
change every 250-500 hours, fuel filter every 500 hours, air filter
inspection every 500 hours, coolant check every 1000 hours. For
standby generators that rarely run, perform a monthly 30-minute test
run at 50%+ load to keep the engine healthy. ZIQI provides a
complete maintenance schedule with every unit.
Related Products
* Specifications subject to change without notice. All generators are
factory-tested at full load before shipping. Voltage, frequency, and
enclosure type customizable at order. Contact ZIQI for your
project requirements.